23104

Ex-XenonStrobe D1xB2X05DC024MB5A1R/A AMB

5J 1-2Hz LM6/316 IP66/67 UL,IECEx / ATEX

Varenr: D1xB2X05024MB5A1R/A
BeskrivelseTeknisk info
Beskrivelse
D1xB2X05 Explosion Proof Xenon Strobe Beacon 5J
 
 
The D1xB2X05 is a globally approved explosion proof 5 Joule Xenon beacon. The robust IP66, Type 4/4X corrosion proof LM6 marine grade aluminium alloy enclosure ensures suitability for all Class I/II Div 1, Zone 1, 2, 21 & 22 applications.
 
Description:
  
Approved to UL1638 and CAN/ULC S526 for fire alarm use the D1xB2X05 beacons produce a high output Xenon flash required for effective signalling in environments with elevated levels of ambient light. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC. The robust enclosure features a threaded flame path, four cable entries. Mounting options include surface via integrated lugs, pendant or by addition of optional multi direction stainless steel bracket. SIL1 compliant to IEC61508 (2010) as standard – SIL2 version available.
 
Features:
 
 • Four flash rates: 1Hz, 1.3Hz, 1.5Hz & double flash
 • Automatic synchronisation on multi-beacon system
 • User replaceable Xenon tube secured against shock & vibration
 • Stainless Steel guard included as standard
 • Field replaceable UV stable lens colour filter
 • Stopping plugs included
 • 4 x side cable entries, 1 x pendant conduit entry
 • Duplicate cable terminations (in & out for daisy-chain installations)
 • UL 1638 Visible signaling devices for Fire Alarm
 • CAN/ULC S526 Visible signaling device for Fire Alarm
 
Approvals:hit
 
 • IECEx UL 15.0003X
   IEC 60079-0 : 2011
   IEC 60079-1 : 2014
   IEC 60079-31 : 2013

 • ATEX DEMKO 15ATEX1448X
   EN 60079-0 : 2012
   EN 60079-1 : 2014
   EN 60079-31 : 2014

Coding:

•II 2G Ex db IIC Gb T6 Ta -50°C to +55°C
•II 2G Ex db IIC Gb T5 Ta -50°C to +70°C
•II 2D Ex tb IIIC Db T95°C Ta -50°C to +70°C
 
Specification:
 
Energy:10 Joules (10Ws)
Flash rate:1Hz (60fpm), 1.5Hz (90fpm) & double flash
  
Peak Candela:1,000,000 cd - calculated from energy (J)
Effective Intensity cd:500 cd - calculated from energy (J)
Peak Candela:110,243 cd - measured ref to I.E.S
Effective Intensity cd:479.39 cd - measured ref to I.E.S
  
Lens colours:Red, Amber, Yellow, Green, Blue, Clear & Magenta, 
Voltages DC: 24vDC; 48vDC
Voltages AC: 115vAC; 230vAC
Ingress protection:IP66
  
Enclosure:UV stable GRP (glass reinforced polyester)
Colour:Natural Red - can be provided in alternative colours
Cable entries: 3 x M20 ISO (2 stopping plugs inc.)
   Adaptors to M25, 1/2" & 3/4" NPT can be specified
Terminals:0.5 to 2.5mm²
  
Tube life:Emissions are reduced to 70% after 8 million flashes
Temp. range:-50° to +70°C (-58°F to +158°F)
Weight: 3.5kg / 7.7lbs
 
 *All candela data is representative of performance with clear lens at optimum voltage.
 
 
Part Codes:
 
(The actual choices for this particular model are highlighted in red)

 
Version:Part code:
             
Product type:GNExB2

  

Type:X10Xenon Beacon - 10 Joule

    

Voltage: [u]02420-28vDC
04842-54vDC
115110-125vAC
230220-240vAC

    

Cable Entry Type: [e]A3 x M20x1.5mm
B2 x 1/2" NPT - adaptors
C2 x 3/4" NPT - adaptors
D2 x M25x1.5mm - adaptors
E1 x 1/2" NPT - adaptor
F1 x 3/4" NPT - adaptor
G1 x M25x1.5mm - adaptor
H3 x 1/2" NPT - adaptors
I3 x 3/4" NPT - adaptors
J3 x M25x1.5mm - adaptors

   

Adaptor/StoppingBBrass
plug material: [m]NNickel Plated
SStainless Steel

   

Guard material: [s]1A2 304 Stainless Steel
2A4 316 Stainless Steel

                 

Product version: [v]A1IECEx & ATEX

   

Enclosure colour: [x]RRed
SSpecial - contact E2S for
alternative enclosure colours

   

Lens colour: /[y] 1R  Red
2A  Amber (Orange)
3Y  Yellow
4G  Green
5B  Blue
7C  Clear (Transparent)
8M  Magenta
 

Example part code:GNExB2 X10 [u] [e] [m] [s] [v] [x] . [y]
Makes this part code :GNExB2 X10 115 A B 2 A1  R . 1
 
Explanation of above
Product type:"GNExB2"
Type:"X10" = 10 Joule Xenon Strobe Beacon
Voltage: [u]"115" = 110-125vAC
Cable Entry: [e]"A" = 3 x M20x1.5mm
Stopping plug: [m]"B" = Brass stopping plug
Guard material: [s]"2" = A4 316 Stainless Steel Guard
Product version: [v]"A1" = IECEx & ATEX certified
Enclosure colour: [x]"R" = Red Enclosure colour
Lens colour: .[y] ."1" = (1) Red Lens colour
 

Effective Candela lens colour factor:
 
RedAmber Yellow GreenBlueClear
0.150.510.860.490.121.00
 
 
Current Consumption:
 
Version:Voltage:Current:
24vDC20-28vDC 592mA
48vDC 42-54vDC233mA
115vAC50/60Hz110-125vAC399mA
230vAC50/60Hz220-240vAC198mA
 
 

Assemblies:
 
The GNExB2X10 is available as a plated assembly configured with up to 4 xenon strobe beacons with or without a GNExJ2 Ex d junction box. Contact us for further information.

 
Teknisk info

Produktinformasjon

Gruppe 1 ALARM & VARSLING
Gruppe 2 Ex Lys
Gruppe 3 Ex Xenon Strobe
Produsent E2S