6399

Ex Sounder GNExS2 24vDC (10-30vDC)

117dB(A) IP66/67 EExd-IIC-T4 45-tones

Varenr: GNEXS2DC024N2A1R
BeskrivelseTeknisk infoTilbehørAlternativer
Beskrivelse
GNExS2 Alarm Horn Sounder 123dB(A)
 
 
The flameproof GNExS2 alarm sounder is suitable for Zone 1 & Zone 2 applications - certified to ATEX and IECEx.
 
 
Sound level ouputs are up to 123dB(A) at 1 metre with a choice of 45 alarm tones and 4 remotely selectable stages. The alarm tone frequencies for the first 2 stages are independently selectable. The GNEx range features enclosures manufactured from GRP (glass reinforced polyester), moulded in natural red, but also available in other colours.
The re-entrant flare horn is high impact, fire retardant ABS. All models have two M20 cable entries, large termination areas containing in & out terminals and an ingress protection of IP66/67.
 
 
Features:
 
• Automatic synchronisation on multi-sounder system.
 • Very large termination area.
 • Ratchet adjustable stainless steel ‘U’ bracket.
 • IN & OUT terminals.
 • Independently selectable tones for 1st & 2nd stages.
 
 
Approvals:
 
ATEX certificate:
SIRA 13ATEX1139X, EN 60079-0 : 2012, EN 60079-1 : 2007
 
IECEx certificate:
IECEx SIR 13.0029X, IEC 60079-0 : 2011 (Ed6), IEC 60079-1 : 2007 (Ed6)

Coding:

 
 • II 2G Ex d IIC T4 Ta. -60° to +50°C
 • II 2G Ex d IIC T3 Ta. -60° to +70°C
 • II 2G Ex d IIB T6 Ta. -60° to +50°C
 • II 2G Ex d IIB T5 Ta. -60° to +65°C
 • II 2G Ex d IIB T4 Ta. -60° to +70°C

 

 
Specification:
 
Maximum output:123dB(A) @ 1 metre [114dB(A) @ 10ft/3m]
Nominal output:117dB(A) @ 1m +/- 3dB - Tone 2
[108dB(A) @ 10ft/3m]
No. of tones:45 (UKOOA / PFEER compliant)
No. of stages:4
Volume control:Max. 117dB(A); Min. 108dB(A) - Tone 2
Effective range:200m/656ft @ 1KHz
Voltages DC:24vDC (10-30vDC), 48vDC (38-60vDC)
Voltages AC:230vAC (100-260vAC/DC)
Stage switching:Negative or positive
Ingress protection:IP66/67
Enclosure matl:GRP (glass reinforced polyester)
Colour:RAL3000 Red
(others available on request)
Flare matl:High impact UL94 V0 & 5VA FR ABS (Red)
Cable entries:Dual M20 ISO
Adaptors to M25, 1/2" & 3/4" NPT can be specified
Terminals:0.5 - 2.5mm² (20-14 AWG)
Enclosure volume:<2 litres
Line monitoring:Blocking diode included
EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor
or diode (DC versions) can be fitted
Weight: DC: 3.35kg/7.37Ibs AC: 3.55kg/7.81Ibs
 
 
 
Part Codes:                       GNEx S2 [u] [m] [s] [v] [x]
 
 
Version:Part code:
             
Product type:GNEx S2
  
Voltage: [u]DC02424vDC (10-30vDC)
DC04848vDC (38-60vDC)
AC230230vAC (110-260vAC)
  
Adaptor/StoppingBBrass
plug material: [m]NNickel Plated
SStainless Steel (Standard)
  
Bracket material: [s]1A2 304 Stainless Steel
2A4 316 Stainless Steel (Standard)
3A2 304 St/St with Equip. Tag
4A4 316 St/St with Equip. Tag (304)
      
Product version: [v]A1Approval to ATEX & IECEx
(Standard)
  
Enclosure colour: [x]RRed RAL3000 (Standard)
SSpecial colour - contact sales
 

Example part code:GNEx S2 [u] [m] [s] [v] [x]
GNEx S2 DC024 S 2 A1 R
 
Explanation of tehe above:
Product type:"GNEx S2"
Voltage: [u]"DC024" = 24vDC (10-30vDC)
Stopping plug[m]"S" = Stainless Steel
Bracket material: [s]"2" = A4 316 Stainless Steel Bracket
Product version: [v]"A1" = Group II 2G/D Zone 1, 2, 21 & 22
Enclosure colour: [x]"R" = Red Enclosure colour
 

 
 
Current Consumption:
 
Version:Voltage:Current:
  24vDC   10-30vDC811mA @ 24vDC
  48vDC   38-60vDC434mA @ 48vDC
115vAC 50/60Hz100-260vAC297mA @ 115vAC
230vAC 50/60Hz100-260vAC196mA @ 230vAC
 
 
 
 
Teknisk info

Produktinformasjon

Ex-Beskyttelse EEx-d (zone 1,2)
Ex-Zone
  • Zone 1 (gas)
  • Zone 2 (gas)
Gruppe 1 ALARM & VARSLING
Gruppe 2 Ex Lyd
Gruppe 3 Ex Elektronisk Alarmhorn
IP Tetthetsgrad
  • IP00 (NA)
  • IP21
  • IP30
  • IP33
  • IP54
  • IP55
  • IP56
  • IP65
  • IP66
Kapslings-Farge Rød
Kategori
  • Anbefalt vare
  • Hovedprodukt
Materiale GRP
Merke-Spenning 24vDC
Modell Serie GNEx Serien i GRP
Monteringsmetode
  • Veggmontering
  • Veggmontering m/festeører
Produsent E2S
Sertifisering
  • ATEX
  • IECEx


Tilbehør
Alternativer