SP75-1011 Sealing O ring for GNEx B1
for all GNEx B1 X05, IECEx & ATEX approved explosion proof 5 Joule Xenon beacons.
Maintenance, repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards:
- EN60079-19/IEC60079-19 Explosive atmospheres - Equipment repair, overhaul and reclamation
- EN60079-17/IEC60079-17 Explosive atmospheres - Electrical installations inspection and maintenance
Units must not be opened while an explosive atmosphere is present.
Electrostatic charging hazard - Clean only with a damp cloth.
The enclosure is non-conducting and may generate an ignition-capable level of electrostatic charges under certain extreme conditions.
The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions that might cause a build-up of electrostatic charges on non-conducting surfaces.
The stainless steel beacon guard is not earthed and may generate an ignition-capable level of electrostatic charges. It has a capacitance of 10pF according to EN/IEC60079-0, clause 7.5.
The flashdome guard must not be removed from the unit at any time whilst in service.